MiniMedTM 780G system

Our most advanced insulin pump system. Self-adjusting* basal insulin pump system with new autocorrection dosing.

 

MiniMed 780G system with Instinct sensor, made by Abbott

Automatically adjusts insulin delivery and corrects highs 24/7, every 5 minutes, as needed.*

Get more out of your diabetes management.

Anticipates

Anticipates insulin needs. Adjusts insulin delivery. Corrects highs automatically while helping to protect from lows1,2.

Adjusts

Self-adjusts insulin delivery to suite needs, up to 288 times per day**.

Corrects

Automatically corrects highs, while helping to prevent lows1,2.

80%
 worldwide average Time in Range

 

91%
 overnight average Time in Range◊,5

 

96%
 fewer injections compared to multiple daily injection therapy‡ 

Discover SmartGuardTM Technology

The MiniMed™ 780G system continuously anticipates insulin needs, adjusts insulin delivery and corrects highs automatically*, while helping to protect your patients from lows1,2. Automatic* adjustments and corrections that help your patients focus on their life – not their glucose levels.

A complete system

MiniMedTM 780G insulin pump

Add icon collapse icon

Based on information received from the CGM every 5 minutes, the insulin pump makes automatic adjustments and corrections to your insulin delivery.

Animation of 780G insulin pump

Continuous glucose monitor (CGM)

Add icon collapse icon

Sensors measure and send sugar levels to the pump. We have all-in-one disposable CGM options. 

Infusion set

Add icon collapse icon

Allows for continuous and discreet delivery of insulin through a thin, flexible tube. Get up to 7 days of wear time with the ExtendedTM infusion set.

Extended infusion set

MiniMed Mobile app

Add icon collapse icon

Glucose levels can now be viewed on their smartphone, allowing them to easily track their values and get notified on their phone if they are going high or low. Available to download at no cost for most iOS and Android smartphones.

CareLink™ Connect App

Add icon collapse icon

Choose to share your real-time diabetes data with their care partners.

Blood glucose meter

Add icon collapse icon

Test results from the Accu-Chek® Guide Link blood glucose meter are sent wirelessly to the pump for quick sensor calibrations.

Tech specs

Waterproof capabilities

At the time of manufacture and when the reservoir and tubing are properly inserted, your pump is waterproof. It is protected against the effects of being underwater to a depth of up to 12 feet (3.6 meters) for up to 24 hours. This is classified as IPX8 rating. See user guide for more details. The sensor and transmitter are water-resistant at 8 feet (2.4 meters) for up to 30 minutes. CGM readings may not be transmitted from the CGM to the pump while in water. The pump is not intended for submersion in water and is expected to be removed prior to swimming or bathing.

Environmental conditions

The MiniMed™ 780G insulin pump system is designed to withstand most conditions encountered in your daily life. Pump operating temperature range is from 41 °F (5 °C) to 98.6 °F (37 °C). Pump storage temperature range is from -4° F (-20° C) to 122° F (50° C). Air pressure range is from 700 hPa to 1060 hPa (10.2 psi to 15.4 psi).

Altitude range

  • Pump operating range is from 10.2 psiA(70.33 kPa) to 15.4 psiA(106.18 kPa)
  • Storage range is from 7.2 psiA(49.64 kPa) to 15.4 psiA(106.18 kPa)

Insulin type

Rapid-acting U100 insulin (Humalog® and NovoLog®) that has been prescribed by a healthcare professional.

Bolus delivery

Bolus Speeds

  • Standard: 1.5 units/minute
  • Quick: 15 units/minute

Programming increments

  • 0.025 units
  • 0.05 units
  • 0.1 units

Max bolus 0 to 25 units

Basal rate delivery

0 to 35 units per hour or the Max Basal Rate amount, whichever is lower.

Screen

  • Color screen with auto-brightness
  • Backlight time out 15 seconds (default), 30 seconds, one minute, three minutes

Battery & power

The pump requires one new AA (1.5 V) battery. For best results, use a new AA lithium (FR6) battery. The pump also accepts an AA alkaline (LR6) or a fully charged AA NiMH (HR6) nickel-metal hydride rechargeable battery.

Pump memory

At any time, you can review 30 days of pump history.

Size

The pump dimensions in inches are approximately 2.1 width x 3.78 length x 0.96 depth. The weight of the pump is approximately 3 ounces.

Warranty

  • Insulin pump: 4 years
  • Guardian™ 4 transmitter: 1 year

Frequently asked questions

Add icon collapse icon

Footnotes

*Compared vs the MiniMed™ 640G system.
Refer to System User Guide-SmartGuard™ feature. Some user interaction required
† Taking a bolus 15 – 20 minutes before a meal helps to keep blood sugar levels under control after eating.

‡ Refers to auto correct, which provides bolus assistance. Can deliver all correction doses automatically without user interaction, feature can be turned on and off.
◊ Due to inherent real-world study limitations, caution is advised when attempting to extrapolate these results to new patients. There could be significant differences. Overnight period: 3:00 AM- 6:00 AM. Number of users with ≥10 days of sensor glucose data; Optimal settings are glucose target at 100 mg/dL (5.5 mmol/L) and Active Insulin Time (AIT) at 2 hours and used >95% of the time.

References

  1. Carlson, A.L. et al. 97-P- Safety and glycaemic outcomes of the MiniMed™AHCL System in subjects with T1D. 80th ADA International Conference, June 2020, Chicago
  2. Collyns .O. et al. 199-OR- Improved glycaemic Outcomes with MiniMed™ AHCL Delivery. 80th ADA International Conference, June 2020, Chicago
  3. Medtronic data on file. Pivotal Trial (Age 14-75). N=157. 2020; 16 US sites
  4. Bergenstal, R. M. et al. Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes Jama. 2016; 316 (13): 1407 – 1408
  5. Battelino T, et al. Clinical targets for continuous glucose monitoring data interpretation: recommendations from the International Consensus on Time in Range. Diabetes Care 2019; 42(8): 1593-1603.
  6. ADA Guidelines https://www.diabetes.org/a1c
  7. Olivia J. Collyns et al. Diabetes Care Apr 2021, 44 (4) 969-975

See the device manuals for detailed information regarding the instructions for use, indications, contraindications, warnings, precautions, and potential adverse events. For further information, contact your local Medtronic representative

Important Safety Information: MiniMedTM 780G system with SmartGuardTM technology with Instinct sensor, Simplera SyncTM sensor, and GuardianTM 4 sensor

The MiniMedTM 780G system is intended for the continuous delivery of basal insulin at selectable rates and the administration of insulin boluses at selectable rates for the management of type 1 diabetes mellitus in persons 7 years of age and older, and of type 2 diabetes mellitus in persons 18 years of age and older requiring insulin. The system is also intended to continuously monitor glucose vales in the fluid under the skin.

The MiniMedTM 780G System includes SmartGuardTM technology, which can be programmed to automatically adjust insulin delivery based on the continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the sensor glucose (SG) value falls below or is predicted to fall below predefined threshold values. The system is intended for use with connected sensors, including the Simplera SyncTM and GuardianTM 4 sensors and integrated continuous glucose monitors, including the Instinct sensor, each of which has different wear-time, form factor, insertion site, and other distinguishing characteristics that relate to sensor performance. Consult the appropriate sensor user guide when using the system. Discuss treatment decisions with your HCP.

WARNING: Do not use the SmartGuardTM feature for people who require less than 8 units or more than 250 units of total daily insulin per day. A total daily dose of at least 8 units, but no more than 250 units, is required to operate in the SmartGuardTM feature.

WARNING: Do not use MiniMedTM 780G system until appropriate training has been received from a healthcare professional. Training is essential to ensure the safe use of MiniMedTM 780G system.

WARNING: Do not use SG values to make treatment decisions, including delivering a bolus, while the pump is in Manual Mode. When the SmartGuardTM feature is active and you are no longer in Manual Mode, the pump uses an SG value, when available, to calculate a bolus amount. However, if your symptoms do not match the SG value, use a blood glucose (BG) meter to confirm the SG value. Failure to confirm glucose levels when your symptoms do not match the SG value can result in the infusion of too much or too little insulin, which may cause hypoglycemia or hyperglycemia.

Pump therapy is not recommended for people whose vision or hearing does not allow for the recognition of pump signals, alerts, or alarms. The safety of the MiniMed™ 780G system has not been studied in pregnant women or in persons using other anti-hyperglycemic therapies that do not include insulin. For complete details of the system, including user guides and important safety information such as indications, contraindications, warnings and precautions associated with system and its components, see https://bit.ly/MiniMedRisks.

©2026 MiniMed. MiniMed and MiniMed logo are trademarks of Medtronic MiniMed, Inc. The sensor shape and appearance, Abbott, and “a” logo are marks and/or designs of the Abbott group of companies in various territories and used under license. Sensor image ©2026 Abbott. TM*Third–party brands are trademarks of their respective owners.

DreaMed Diabetes is a trademark of DreaMed Diabetes, Ltd. The MiniMedTM 780G system algorithm includes technology developed by DreaMed Diabetes.