CGM and Sensors
Product Support

Simplera SyncTM sensor

Watch this video for guidance on how to insert the new Simplera SyncTM sensor and connect it to your MiniMedTM 780G insulin pump.

Click below to see a "What's New" resource with details on the latest enhancements to the MiniMedTM 780G pump software when used with the Simplera SyncTM sensor.

 

Getting Started with the Simplera SyncTM sensor for the MiniMedTM 780G system - (3:10)

Learn about wear locations, how it's inserted, and how to connect it to your pump.

GuardianTM 4 sensor

Insertion in the arm for best performance and longest wear

Rob performs an arm insertion of a GuardianTM 4 sensor - (3:36)

Watch to see #MiniMedChampion Rob Howe demonstrate a Guardian 4 sensor insertion!

Getting started with MiniMed CGM

GuardianTM sensor CGM - insertion, programming and Quick Start - (13:42)

Topics include: starting a GuardianTM sensor CGM with your MiniMedTM 780G, sensor insertion, alert setup & when to use a BG.

Guardian 4 continuous glucose sensor

Sensor replacement

Guardian 4 continuous glucose sensor

Having an issue with your sensor? Request a replacement through the MiniMed WeCare Mobile App or the form linked below. Replacements will be quickest through the WeCare App.

Answers to common questions

What is a glucose sensor?

Add icon collapse icon

A glucose sensor is a tiny electrode that measures your glucose levels. It sits under the skin in your interstitial fluid. Glucose sensors are easily inserted using an automatic insertion device: a needle is used to insert the glucose sensor. The needle is then removed leaving just the tiny flexible electrode under the skin. The glucose sensor is connected to a transmitter, either all-in-one with the sensor or a separate device, so that readings can be transmitted to your insulin pump.

Do I still need to do fingerstick readings if I use glucose sensors?

Add icon collapse icon

When using the MiniMedTM 780G with the Simplera SyncTM sensor or GuardianTM 4 sensor, there are no fingersticks required with SmartGuardTM technology**. There are times when it is appropriate to enter a fingerstick BG into the MiniMedTM 780G system, or when the system may sometimes request one. You should use a reading from a BG meter instead of a sensor glucose reading in certain cases. Please review the videos above to learn more. When using the GuardianTM Sensor (3), calibrations in the form of a BG by fingerstick are required at least every 12 hours. ​When using either sensor not in SmartGuardTM tech, a BG reading should be used before making treatment decisions.

 

**A blood glucose (BG) reading is needed to enter SmartGuardTM. If symptoms don’t match alerts & readings, use a BG meter. Refer to user guide.

Where should I wear my glucose sensor?

Add icon collapse icon

Although indicated in multiple areas depending on age, it has been found that wearing the Simplera SyncTM sensor and GuardianTM 4 sensor on the back of the upper arm may provide the best sensor life and experience. Therefore, it is the recommendation that patients first try insertion on the back of the arm, if they are able to do so.

Simplera SyncTM sensor

 

GuardianTM 4 sensor

 

GuardianTM Sensor (3)

How long do sensors last? Do they expire?

Add icon collapse icon

The Simplera SyncTM sensor, GuardianTM 4 sensor and GuardianTM Sensor (3) can be worn for up to 7 days. Remember, the transmitter is re-usable and should be re-charged after each sensor wear. No transmitter is required when using the Simplera SyncTM sensor.

What is the warranty on my transmitter?

Add icon collapse icon

Both the GuardianTM 4 transmitter and GuardianTM Link (3) transmitters come with a 12-month warranty. No transmitter is required when using the Simplera SyncTM sensor.

What type of batteries does the transmitter use?

Add icon collapse icon

Both the GuardianTM 4 transmitter and GuardianTM Link (3) Transmitters have a self-­contained battery, which can be recharged using the charger supplied, but cannot be changed. As it has a self­contained battery, the transmitter should be disposed of, or recycled, in accordance with local governing ordinances and recycling guidelines. No transmitter is required when using the Simplera SyncTM sensor.

How do I renew my out-of-warranty GuardianTM 4 Transmitter?

Add icon collapse icon

If your GuardianTM 4 Transmitter is out of warranty or will expire soon, you can request a renewal through your MiniMedTM eShop account. Look for the “Guardian 4 Transmitter Renewal” offer under your Exclusive Deals, add it to your cart, and complete your order. No transmitter is required when using the Simplera SyncTM sensor.

How do I pair my new transmitter?

      Add icon collapse icon
      1. Attach the transmitter to the charger.
      2. On your pump, from the Home screen, open the Menu and go to the devices settings.
      3. Place the transmitter, still attached to the charger, next to the pump.
      4. Select Pair New Device. The Searching screen appears.
      5. Remove the transmitter from the charger. The transmitter light flashes 10 times, then turns off. The Select Device screen appears with a list of available devices.
      6. Select the CGM device that matches the serial number on the back of the transmitter.
      7. Check that the serial number on the pump screen matches the serial number on the transmitter. Select Confirm. Use Back if the number is incorrect.

      Success message: If the connection completes, the pump shows Pairing successful!

      No transmitter is required when using the Simplera SyncTM sensor.

       

      I have insurance - can you tell me if sensors are covered?

      Add icon collapse icon

      Many insurance plans cover CGM, resulting in little or sometimes even no out-of-pocket cost. Insurance coverage for CGM may vary depending on the sensor model. Check out our CGM Coverage webpage for more details and how we can help you investigate your coverage.

      How can I replace a lost sensor?

      Add icon collapse icon

      Request a replacement through the MiniMed WeCare Mobile App or our Sensor Replacement Form. Replacements will be quickest through the WeCare App.

      Alternatively you can call our Technical Support team 24/7 at 1.800.284.4416, option 1 for troubleshooting and replacements of lost sensors.