MiniMed Champion Aria dancing with MiniMed Fit
MiniMed Champion Jaylen running with MiniMed Fit
MiniMed Champion Ciara with coffee and MiniMed Fit
MiniMed Champion Chris on tennis court with MiniMed Fit

MiniMed Fit tubeless insulin pump system

A tubeless insulin pump that combines up to 7 days of wear and a 300-unit insulin cartridge, which means a whole week where you’re not planning around a change.‡,§

Everything a tubeless pump should be

Longer wear without interruption.‡ Less to think about.

Automatically adjusts and corrects

The system works to stabilize your sugar levels, adjusting insulin delivery and correcting your levels every 5 minutes.†


Fewer changes without interruption. More freedom.

MiniMed Fit is the only tubeless pump you can wear for 7 days without interruption,‡ that holds 300 units of insulin. That means no more daily injections and less time spent managing


Easy to wear and use

Tubeless, discreet, and fully phone-controlled — the system fits seamlessly into your life. 

Waterproof∞

Pump is waterproof up to 8 feet (2.4 meters) for 1 hour and 45 minutes.

Get to know the system

MiniMed Fit tubeless pump

Add icon collapse icon

The only tubeless insulin pump that combines up to 7 days of wear and a 300-unit insulin cartridge, which means up to a whole week where you’re not planning around a change.‡,§

Using data from your CGM, the pump automatically adjusts insulin delivery and corrects glucose levels every 5 minutes to help stabilize your glucose levels.† When your sugar level is trending low, the system pauses insulin delivery. If your sugar level is trending high, the system will give correction doses.

MiniMed Fit pump animation

Continuous glucose monitor (CGM)

Add icon collapse icon

The CGM delivers readings to the pump every 5 minutes to enable the automation of SmartGuardTM technology. 
 
 

Simplera SyncTM sensor — An all-in-one disposable sensor giving you a once-a-week change with up to 6 days of wear, plus 24-hour grace period.

Simplera Sync sensor

Mobile apps

Add icon collapse icon

MiniMedTM app — Allows you to see insulin pump data and glucose levels on your smart device in addition to your pump screen.

Apple App Store →
Google Play Store →

CareLinkTM Connect app — Share your pump information with up to 5 care partners so they can view your glucose levels and get alerts wherever they are.

Apple App Store →
Google Play Store →

MiniMed app on phone and watch screen

Compare latest insulin pump systems

MiniMed FitTM system

Omnipod® 5

Tandem Mobi Tubeless

Beta Bionics® Mint

Up to 7 days of wear without catridge change‡

Yes
No
No
No

Meal DetectionTM technology
Helps correct for rising glucose after meals

Yes
No
No
No

Auto correction bolus†

Every 5 mins
 Up to 8% of the TDD††

—

Every 60 mins
Limited to 6 units‡‡

Every 5 mins
Limited to 3 units‡‡

Automated basal delivery
every 5 minutes

Yes
Yes
Yes
Yes

300-unit capacity

Yes
No
No
No

Stay in the know

MiniMed Fit is not yet available. Sign up to get emailed when we have more information about product availability and ordering. 

indicates a required field.

*
This field is required.
*
This field is required.
*
This field is required.
*
This field is required.
*
This field is required.
*
This field is required.

This form is for customers in the Unites States only. For more information about our products in your region please see our list of international locations.

This field is required.

By checking this box, I agree to receive promotional SMS messages from MiniMed at the mobile number provided. Message frequency varies. Message and data rates may apply. Reply STOP to opt out or HELP for support. Consent is not a condition of purchase. View our Privacy Policy and Terms & Conditions.

HIPAA Marketing Authorization

MiniMed respects the privacy of all our customers. With your permission, we may use your protected health information, including your contact information and health-related data, for marketing purposes, promotional offers, survey opportunities, and advertising that we think may be of interest to you. We may also share your information with MiniMed representatives and contractors who are assisting us with these activities.

I understand that this Authorization may permit MiniMed to contact me by text message, telephone, or email. With respect to text messages, I consent to receiving text messages at the phone number(s) submitted using automated technology from or on behalf of MiniMed, concerning the marketing, advertising, and/or offers of sale of MiniMed products, therapies, and services. I also certify that I am (a) age 18 or older and (b) authorizing and consenting to use of the information provided for MiniMed to contact me. My consent is not a condition for purchase. Airtime, message, and data rates may apply. I may opt out at any time by (i) texting "STOP" in reply to a text; (ii) sending an email to takecontrol@medtronic.com; or (iii) signing into my MiniMed myHome profile and updating my communication preferences (www.diabetes.shop/communication).

Please note that this Authorization is optional, and you may refuse to opt in. If you do not want to opt in, it will not affect your treatment, health insurance eligibility, or benefits, and you will not be stopped or prevented from accessing the CareLink™ Personal system, or other MiniMed products, mobile apps, or services.

This Authorization will expire ten (10) years from the date you submit it online. You may revoke it by:

Opting out will not affect actions already taken. Information disclosed may be re-disclosed and no longer protected by federal privacy standards. Questions? Contact Customer Service at 800-646-4633 or takecontrol@medtronic.com.

This field is required.

Your form was successfully submitted.

Mom holding phone with MiniMed app with children playing soccer,

MiniMed Fit will be available through your pharmacy benefit

Mom holding phone with MiniMed app with children playing soccer,

The MiniMed Fit insulin pump will be available to people with diabetes who have commercial insurance. 

For your CGM, we'll verify your insurance benefits — whether that's through your pharmacy benefit or durable medical equipment (DME) benefit. 

MiniMed Fit is a new product and health plan coverage is being established. If you have Medicare or Medicaid, it may take more time until MiniMed Fit is covered by your plan.

Tech specs

Size and weight

  • Size: 2.46 inches length x 1.68 inches width x 0.6 inches height
  • Weight: 36 grams (when filled with 300 units of insulin)

Parts of the pump

  1. Disposable cartridge — Holds 300 unites of insulin, with a built-in cannula and reliable adhesive for up to 7 day wear.
  2. Reusable pump core — The brains of the pump, this rechargeable part attaches to the disposable cartridge. One charge lasts up to 7 days.


MiniMed Fit labeled

Compatible insulin

The MiniMed Fit system is intended for use with the following compatible U-100 insulins:

  • U-100 AdmelogTM*
  • U-100 HumalogTM*
  • U-100 NovoLogTM*

Waterproof capabilities

The MiniMed Fit is waterproof up to 8 feet (2.4 meters) for 1 hour and 45 minutes. If you choose to stay connected while in water, CGM readings may not be transmitted to the pump.

Environmental conditions

The Fit pump system is designed to withstand most conditions encountered in your daily life. Pump operating temperature range is from 41 °F to 93 °F (5 °C to 34 °C). Pump storage temperature range is from -4° F (-20° C) to 122° F (50° C). Storing the pump in temperatures outside of this range can damage the pump.

Bolus delivery

The pump delivers small doses of insulin. The smallest dose of insulin is 0.05 units.

Increments

  • 0.1 units (default)
  • 0.01


Max bolus 25 units

Basal rate delivery

Minimum basal insulin increment: 0.050 units/hour.
Above 0.050, increments can be set in 0.025-unit increments (e.g., 0.05, 0.075, 0.1, etc.).


Max basal 15 units

Battery and power

The pump uses a wall charger. It takes approximately 30 minutes for a full charge, and a full charge will last at least 7 days.

MiniMed Fit charging 

Wear locations

You can choose to wear the pump on the abdomen, back of upper arm, thigh, lower back, or upper buttocks. For persons 7-17 years of age, insert the pump in the upper arm or thigh for best wear duration. Using the lower back, upper buttocks, or abdomen may result in shorter wear duration for this age group.

Frequently asked questions

What is the MiniMed Fit system?

Add icon collapse icon

The MiniMed Fit system is MiniMed’s next‑generation insulin delivery system that combines a small, tubeless insulin pump, SmartGuardTM advanced hybrid closed loop technology, a compatible CGM sensor, and the MiniMedTM app to support connected, automated diabetes management.

Who can use MiniMed Fit?

Add icon collapse icon

The MiniMed Fit system is cleared for those living with Type 1 diabetes ages 7 and up, and those living with Type 2 diabetes ages 18 and up.

How is the MiniMed Fit pump different from Omnipod 5?

Add icon collapse icon

The MiniMed Fit pump lasts up to 7 days and holds 300 units of insulin — so it holds more insulin and lasts twice as long without interruptions as other tubeless pumps.‡

Does MiniMed Fit use the same SmartGuardTM algorithm as MiniMed Flex & MiniMed 780G?

Add icon collapse icon

Yes. MiniMed Fit uses the same SmartGuardTM advanced hybrid closed loop algorithm that powers the MiniMed Flex and MiniMed 780G system.

Which CGM sensors are compatible with MiniMed Fit?

Add icon collapse icon

MiniMed Fit is currently cleared to work with the Simplera SyncTM sensor. 

Which phones are compatible with the MiniMedTM app?

Add icon collapse icon

You can check device compatibility for the latest updates on supported devices.

Footnotes

† Refers to SmartGuard™ feature. Individual results may vary.
‡ 7 day wear without cartridge change possible with <42U TDD. Tandem Mobi can be worn up to 7 days with a required cartridge change at 3 days. Omnipod can be worn up to 3 days. Mint has 3-day wear, plus a 12-hour grace period for insulin delivery. See user guides for more.
§ Omnipod, Mint, and Mobi tubeless devices hold 200 units. See product IFUs for details.
◊ Due to inherent real-world study limitations, caution is advised when attempting to extrapolate these results to new patients. There could be significant differences.

¶ Taking a bolus 15-20 min before a meal provides significant improvement in post meal control.
# 7-day wear achievable with 42 units of total daily dose. Total daily dose may impact frequency of changes
∆ Overnight period: 12:00 AM- 6:00 AM. Number of users with ≥10 days of sensor glucose data; Optimal settings are glucose target at 100 mg/dL (5.5 mmol/L) and Active Insulin Time (AIT) at 2 hours and used >95% of the time.
∞ Pump is waterproof up to 8 feet (2.4 meters) for 1 hour and 45 minutes. CGM readings may not be transmitted from the CGM to the pump while in water.

References

  1. Choudhary P, et al. Diabetes Technol Ther 2024;26 (Suppl. 3):S32-S37.15
  2. McVean JJF, Niu F, Liu M, et al. Automated insulin delivery with the MiniMed™ 780G system reduces burden by improving sleep and glycaemic control overnight. Diabetes Obes Metab. 2026;28(3):2456-2460. doi:10.1111/dom.70380
  3. Data on File, Abbott Diabetes Care, Inc.
  4. Alva, Shridhara, Ronald Brazg, Kristin Castorino, Mark Kipnes, David R. Liljenquist, and Hanqing Liu. "Accuracy of the Third Generation of a 14-Day Continuous Glucose Monitoring System." Diabetes Therapy 14, no. 4 (2023): 767-776. https://doi.org/10.1007/s13300-023-01385-6

Important Safety Information: MiniMed FitTM system with SmartGuardTM technology with Simplera SyncTM Sensor  

The MiniMed FitTM system is intended for the continuous delivery of basal insulin at selectable rates, and the administration of insulin boluses at selectable rates for the management of type 1 diabetes mellitus in persons 7 years of age and older, and of type 2 diabetes mellitus in persons 18 years of age and older requiring insulin. The system is also intended to continuously monitor glucose values in the fluid under the skin. The MiniMed FitTM system includes SmartGuardTM technology, which can be programmed to automatically adjust insulin delivery based on continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the SG value falls below or is predicted to fall below predefined threshold values.

The Simplera SyncTM sensor can be used one time and has a life up to 6 days, followed by a grace period of 24 hours. During the grace period, the sensor will continue to work as it did during the first 6 days, to allow the patient to change their sensor more flexibly. However, some sensors may not survive the full wear period for a variety of reasons. Please be prepared to replace the sensor during the grace period to ensure sensor glucose values continue to be monitored. 

The Simplera SyncTM sensor is not intended to be used directly to make therapy adjustments while the MiniMed FitTM system is operating in manual mode. All therapy adjustments in Manual mode should be based on measurements obtained using a blood glucose meter and not on values provided by the Simplera SyncTM sensor. The Simplera SyncTM sensor has been studied and is approved for use in patients ages 7 years and older and in the arm insertion site only. Do not use the Simplera SyncTM sensor in the abdomen or other body sites, including the buttocks, due to unknown or different performance that could result in hypoglycemia or hyperglycemia.  

The Medtronic MiniMed FitTM System consists of the following devices: MiniMed FitTM Insulin Pump and the Simplera SyncTM sensor. The system requires a prescription from a healthcare professional. 

WARNING: Do not use the SmartGuardTM feature for people who require less than 8 units or more than 250 units of total daily insulin per day. A total daily dose of at least 8 units, but no more than 250 units, is required to operate in the SmartGuardTM feature.

WARNING: Do not use the MiniMed FitTM system until appropriate training has been received from a healthcare professional. Training is essential to ensure the safe use of the MiniMed FitTM system. 

WARNING: Do not use SG values to make treatment decisions, including delivering a bolus, while the pump is in Manual Mode. When the SmartGuardTM feature is active and you are no longer in Manual Mode, the pump uses an SG value, when available, to calculate a bolus amount. However, if your symptoms do not match the SG value, use a blood glucose (BG) meter to confirm the SG value. Failure to confirm glucose levels when your symptoms do not match the SG value can result in the infusion of too much or too little insulin, which may cause hypoglycemia or hyperglycemia. 

Pump therapy is not recommended for people whose vision or hearing does not allow for the recognition of pump signals, alerts, or alarms. The safety of the MiniMed FitTM system has not been studied in pregnant women or in persons using other anti-hyperglycemic therapies that do not include insulin. For complete details of the system, including user guides and important safety information such as indications, contraindications, warnings and precautions associated with system and its components, see https://link.minimed.com/Risks.