You're doing a lot.
A pump can do more.

The MiniMed FlexTM insulin pump system adjusts and corrects sugar levels to protect against highs and lows so you can enjoy more freedom every day.

MiniMed Flex system

From multiple daily decisions to automatic adjustments

Powered by SmartGuardTM technology, the MiniMed Flex system works day and night to continuously adjust insulin delivery every 5 minutes.

Get more support managing insulin throughout the day with automatic insulin adjustments and corrections* every 5 minutes, including support if you miscalculate carbs or occasionally miss a meal dose.§ A 7-day infusion set means changing your infusion set once a week — for up to 96% fewer injections compared with multiple daily injections.*

 

Why people using injections make the switch

Smartphone and watch icon blue

Control from your phone 

Bolus and see your sugar levels through the MiniMed mobile app.

Icon

Small and discreet

Enjoy a pump small enough to tuck away, with room for 300 units of insulin.

Battery charging icon

Water-ready

Waterproof up to 8 feet for up to 105 minutes

Wifi icon

Your choice of sensor

Choose between the 15-day Instinct sensor or the Simplera Sync sensor for once-a-week changes.

Designed so you spend more time in range

80% 

Time in Range
Shown in real-world results when using recommended settings for more good moments all day.1


91%

Overnight Time in Range
Delivered on average overnight for a more restful tomorrow.2

See what more freedom can look like

Complete the form below to begin your coverage check.

indicates a required field.

*
This field is required.
This field is required.
This field is required.

You indicated that you’re not using insulin to manage your diabetes. Our insulin pumps are approved for the continuous delivery of insulin, so this device may not be a good fit for you at this time.

We have other resources that may be helpful for you:


If your circumstances change, please check back with us and we’d be happy to discuss therapy options that may fit your needs.

You indicated that you’re not using insulin to manage your diabetes. Our insulin pumps are approved for the continuous delivery of insulin, so this device may not be a good fit for you at this time.

We have other resources that may be helpful for you:


If your circumstances change, please check back with us and we’d be happy to discuss therapy options that may fit your needs.

This field is required.
This field is required.
This field is required.
*
This field is required.
*
This field is required.
*
This field is required.
*
This field is required.
*
This field is required.
*
This field is required.

This form is for customers in the Unites States only. For more information about our products in your region please see our list of international locations.

By checking this box, I agree to receive promotional SMS messages from MiniMed at the mobile number provided. Message frequency varies. Message and data rates may apply. Reply STOP to opt out or HELP for support. Consent is not a condition of purchase. View our Privacy Policy and Terms & Conditions.

HIPAA Marketing Authorization

MiniMed respects the privacy of all our customers. With your permission, we may use your protected health information, including your contact information and health-related data, for marketing purposes, promotional offers, survey opportunities, and advertising that we think may be of interest to you. We may also share your information with MiniMed representatives and contractors who are assisting us with these activities.

I understand that this Authorization may permit MiniMed to contact me by text message, telephone, or email. With respect to text messages, I consent to receiving text messages at the phone number(s) submitted using automated technology from or on behalf of MiniMed, concerning the marketing, advertising, and/or offers of sale of MiniMed products, therapies, and services. I also certify that I am (a) age 18 or older and (b) authorizing and consenting to use of the information provided for MiniMed to contact me. My consent is not a condition for purchase. Airtime, message, and data rates may apply. I may opt out at any time by (i) texting "STOP" in reply to a text; (ii) sending an email to takecontrol@medtronic.com; or (iii) signing into my MiniMed myHome profile and updating my communication preferences (www.diabetes.shop/communication).

Please note that this Authorization is optional, and you may refuse to opt in. If you do not want to opt in, it will not affect your treatment, health insurance eligibility, or benefits, and you will not be stopped or prevented from accessing the CareLink™ Personal system, or other MiniMed products, mobile apps, or services.

This Authorization will expire ten (10) years from the date you submit it online. You may revoke it by:

Opting out will not affect actions already taken. Information disclosed may be re-disclosed and no longer protected by federal privacy standards. Questions? Contact Customer Service at 800-646-4633 or takecontrol@medtronic.com.

This field is required.

If you arrived on this site via a social media platform, by submitting this form you agree that Medtronic Diabetes may share your visit to this site with that platform. This information may be used and/or re-disclosed by the originating site under their own privacy practices. See our Privacy Policy for more information. Click here to request information without submitting this form.

MiniMed Champion Abby with Flex pump MiniMed Champion Abby with Flex pump

"I didn’t realize how much mental energy I was spending on diabetes every day. The biggest difference since using MiniMed is the peace of mind.”

Abby

MiniMed Champion

Using MiniMed Flex system

Tech specs

Size and weight

  • Size: 3.8 inches length x 1.0 inches width x 1.4 inches depth
  • Weight: 73 grams (without consumables)

MiniMed Flex pump size labeled 

Compatible insulin

The MiniMed Flex system is intended for use with the following compatible U-100 insulins:

  • U-100 AdmelogTM*
  • U-100 HumalogTM*
  • U-100 NovoLogTM*
  • U-100 FiaspTM*
  • U-100 LyumjevTM*

Waterproof capabilities

The MiniMed Flex pump is waterproof up to 8 feet (2.4 meters) for 1 hour and 45 minutes (105 minutes) if you choose to stay connected while in water.

Environmental conditions

The FlexTM 780G pump system is designed to withstand most conditions encountered in your daily life. Pump operating temperature range is from 41 °F to 93 °F (5 °C to 34 °C). Pump storage temperature range is from -4° F (-20° C) to 122° F (50° C). Storing the pump in temperatures outside of this range can damage the pump.

Altitude range

  • Storage range: 10.2 psiA to 15.4 psiA
  • Pump operating range: 10.2 psiA to 15.4 psiA

Bolus delivery

The pump delivers small doses of insulin. The smallest dose of insulin is 0.05 units.

Increments

  • 0.1 units (default)
  • 0.01


Max bolus 25 units

Basal rate delivery

Minimum basal insulin increment: 0.050 units/hour.
Above 0.050, increments can be set in 0.025-unit increments (e.g., 0.05, 0.075, 0.1, etc.).


Max basal 15 units

Battery and power

The pump uses a wall charger. It takes approximately 30 minutes for a full charge, and a full charge will last at least 7 days.

MiniMed Flex pump and charger labeled 

Warranty

Insulin pump: 4 years standard. Some insurances allow up to 5 years (see your insurance details to confirm).

Compatible
products

Reservoir

ExtendedTM Reservoir MMT-342, 10PK. 3.0 ml (300 units)

Infusion sets

MiniMed offers a wide range of infusion sets so that you can choose the right one for your comfort and safety.

Continuous glucose monitor

Simplera SyncTM sensor

Accessories

There are many ways to wear your insulin pump. You can attach your pump to your waistband or belt, protect it in your pocket, or even clip it under clothing. 

Frequently asked questions

Add icon collapse icon

Footnotes
‡ Refers to SmartGuardTM feature. Individual results may vary.

§ Taking a bolus 15 – 20 minutes before a meal helps to keep blood sugar levels under control after eating.

◊ Due to inherent real-world study limitations, caution is advised when attempting to extrapolate these results to new patients. There could be significant differences.

¶ Time frame measured is between 12:00 A.M. and 6:00 A.M.
* Assumes 4 injections per day for 30 days and one infusion set change every seven days.

References

  1. Arrieta A, et al. Diabetes Obes Metab. 2022;10.1111/dom.14714 .
  2. McVean JJF, Niu F, Liu M, et al. Automated insulin delivery with the MiniMed™ 780G system reduces burden by improving sleep and glycaemic control overnight. Diabetes Obes Metab. 2026;28(3):2456-2460. doi:10.1111/dom.70380 

Important Safety Information: MiniMed FlexTM system with SmartGuardTM technology with Simplera SyncTM sensor and Instinct sensor

The MiniMed FlexTM system is intended for the continuous delivery of basal insulin at selectable rates, and the administration of insulin boluses at selectable rates for the management of type 1 diabetes mellitus in persons 7 years of age and older, and of type 2 diabetes mellitus in persons 18 years of age and older requiring insulin. The system is also intended to continuously monitor glucose values in the fluid under the skin. 

The MiniMed FlexTM system includes SmartGuardTM technology, which can be programmed to automatically adjust insulin delivery based on continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the SG value falls below or is predicted to fall below predefined threshold values. The system is intended for use with connected sensors, including the Simplera SyncTM sensor and integrated continuous glucose monitors, including the Instinct sensor, each of which has different wear-time, form factor, insertion site, and other distinguishing characteristics that relate to sensor performance. Consult the appropriate sensor user guide when using the system.  Discuss treatment decisions with your HCP. 

WARNING: Do not use the SmartGuardTM feature for people who require less than 8 units or more than 250 units of total daily insulin per day. A total daily dose of at least 8 units, but no more than 250 units, is required to operate in the SmartGuardTM feature.  

WARNING: Do not use the MiniMedTM Flex system until appropriate training has been received from a healthcare professional. Training is essential to ensure the safe use of the MiniMedTM Flex system. 

WARNING: Do not use SG values to make treatment decisions, including delivering a bolus, while the pump is in Manual Mode. When the SmartGuardTM feature is active and you are no longer in Manual Mode, the pump uses an SG value, when available, to calculate a bolus amount. However, if your symptoms do not match the SG value, use a blood glucose (BG) meter to confirm the SG value. Failure to confirm glucose levels when your symptoms do not match the SG value can result in the infusion of too much or too little insulin, which may cause hypoglycemia or hyperglycemia. 

Pump therapy is not recommended for people whose vision or hearing does not allow for the recognition of pump signals, alerts, or alarms. The safety of the MiniMed FlexTM system has not been studied in pregnant women or in persons using other anti-hyperglycemic therapies that do not include insulin. For complete details of the system, including user guides and important safety information such as indications, contraindications, warnings and precautions associated with system and its components, see https://bit.ly/MiniMedRisks.

 

©2026 Medtronic MiniMed, Inc. MiniMed and MiniMed logo are trademarks of Medtronic MiniMed, Inc. The sensor shape and appearance, Abbott, and “a” logo are marks and/or designs of the Abbott group of companies in various territories and used under license. Sensor image ©2026 Abbott. TM*Third–party brands are trademarks of their respective owners.